Star 215 contains five battery packs and one battery controller, modular power conversion system, BMS system, liquid Cooling Type system and Fire protection system. The battery cell is the smallest basic unit. BMS mainly contains BCU, BMU, EMS, responsible for collecting cell, electric box and electric cabinet information, and communicate with other devices. And provide local energy management services. The liquid Cooling Type system is responsible for the Cooling Type and heating of the entire electrical cabinet system. The fire control system is responsible for the fire status detection and fire prevention of the entire electrical cabinet system.
Cabinet Spec
DC |
Battery Type | LFP |
Cell Configurations | 1P240S | |
Rated Capacity (Ah) | 280 | |
Rated Energy (KWh) | 215 | |
Rated Voltage (V) | 768 | |
Rated Power (KW) | 100 | |
Rated Charge/Discharge Rate | 0.5C | |
Voltage Range (V) | 672 864 | |
Standard Charge/Discharge Current (A) | 140/140 | |
Cooling Type | Liquid Cooling | |
Coolant |
Ethylene glycol: aqueous solution
|
|
Life Cycles | 6000 | |
Fire Suppression | NOVEC1230/FM200, optional | |
Detector |
Smoke, heat & flammable gas detectors |
|
AC |
Rated AC power | 100kW |
AC overload Capacity(KVA) | 1.1 times long-term, 1.2 times 1min | |
Connection Mode | Three-Phase Four-Wire System | |
On-grid AC Voltage | 380V - | |
On- grid Frequency | 50Hz/60Hz±2.5Hz | |
Total Harmonic Distortion | full load) |
Power Factor | -0.99~+0.99 | ||
DC component of current |
|
||
Charge discharge conversion time | 100ms | ||
Max. Conversion Efficiency |
|
||
Cooling Type | Forced air Cooling | ||
System |
Charging Operating Temperatures Range (°C) | -30°C~55°C(>45°C, derating) | |
Discharging Operating Temperatures Range(°C) | -30°C~55°C(>45°C, derating) | ||
Storage Temperatur e Range |
Short term (<1month)(°C) | -30°C 60°C | |
Long term (<1year)(°C) |
0°C 35°C |
||
Noise |
|
||
Dimensions(W*D*H)(mm) | 935*1250*2340mm | ||
Weight(T) | 2.7±0.1 | ||
Anti-corrosion | C4/C5 (optional) | ||
IP Rating |
Battery compartment: IP65 Electrical compartment: IP54 |
||
Relative Humidity | 0- condensing) | ||
Standard Altitude(m) |
|
||
Efficiency |
|
||
Communication Interface | CAN, Ethernet | ||
Communication Protocol | Modbus TCP/RTU | ||
Operation Mode |
Peak load shifting | Yes | |
Demand control | Yes | ||
Economic operation mode | Yes | ||
Reactive power regulation | Yes | ||
Power grid dispatch connection | Yes | ||
Remote dispatch connection | Yes | ||
Local data storage | Yes | ||
Anti-reflux | Optional | ||
Certificatio n standards |
BMS | UL60730, GB/T34131-2017 | |
Battery |
GB/T36276-2018, IEC62619, UL1973, UL9540A |
||
PCS |
CE; EN50549-1:2019+AC.2019-04; CE1 0-21; CE10-16; NRS 097-21-1: :2017; EN50549+Deviations of Netherlands; C10/11: 2019; GB/T 34120; GB/T 34133 |
System composition
Application
Island micro grid, Power stations with new or distributed energy access;
Small fire peak and frequency modulation power station
Outdoor temporary heavy duty center, Load fluctuations of the factory,
enterprise, business center etc.
Send your inquiry directly to us